Quiz-summary
0 of 17 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
Information
NATE / ICE Free Practice Test 8 Questions Answers
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 17 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- Answered
- Review
-
Question 1 of 17
1. Question
1 pointsScrew compressors have almost nonlinear capacity control mechanism:
Correct
Incorrect
-
Question 2 of 17
2. Question
1 pointsCentrifugal compressors are constant speed machines:
Correct
Incorrect
-
Question 3 of 17
3. Question
1 pointsA ________ maintains the refrigerant liquid level and pressure difference necessary for the refrigerant condensing action:
Correct
Incorrect
-
Question 4 of 17
4. Question
1 pointsDischarge Bypass Valves (DBV) responds to the change in downstream or suction pressure:
Correct
Incorrect
-
Question 5 of 17
5. Question
1 pointsThe filter drier is located in the _______ at the outlet of the condenser:
Correct
Incorrect
-
Question 6 of 17
6. Question
1 pointsOne MBH is equivalent to ______ BTU’s per hour
Correct
Incorrect
-
Question 7 of 17
7. Question
1 points_______ Heat that can be measured or felt
Correct
Incorrect
-
Question 8 of 17
8. Question
1 pointsA condition in which a quantity of liquid enters the compressor causing hammering and possible compressor damage.
Correct
Incorrect
-
Question 9 of 17
9. Question
1 pointsInduction motor always operated with ______ power factor:
Correct
Incorrect
-
Question 10 of 17
10. Question
1 pointsPurging refers to the release of air or noncondensable gases from the system:
Correct
Incorrect
-
Question 11 of 17
11. Question
1 pointsA _______ uses a piston moving inside a cylinder to compress the refrigerant:
Correct
Incorrect
-
Question 12 of 17
12. Question
1 pointsA energy-efficient room air conditioner will have an Energy Efficient Ratio (EER) rating of _____ or higher:
Correct
Incorrect
-
Question 13 of 17
13. Question
1 pointsFan pressures will vary directly as the _______ of the rpm ratio:
Correct
Incorrect
-
Question 14 of 17
14. Question
1 pointsSmoke chamber should be constructed so that slopes at ______ angle from the smoke shaft to the flue opening:
Correct
Incorrect
-
Question 15 of 17
15. Question
1 pointsFireman switch is the device that allows the circulator pump to continue operating upto ______ minutes after the heater has shut-off:
Correct
Incorrect
-
Question 16 of 17
16. Question
1 pointsIn boiler safety valves can be used to vent:
Correct
Incorrect
-
Question 17 of 17
17. Question
1 pointsHeat pumps operating cost is much _____ compared to electrical heating:
Correct
Incorrect