Quiz-summary
0 of 15 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
Information
EPA 608 Free Online Practice exam Questions Answers: Core exam 9
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- Answered
- Review
-
Question 1 of 15
1. Question
1 pointsRecovery cylinders are designed for refilling:
Correct
Disposable Cylinders shall be used for carrying virgin or reclaimed refrigerants.
Incorrect
Disposable Cylinders shall be used for carrying virgin or reclaimed refrigerants.
-
Question 2 of 15
2. Question
1 pointsAn overfilled cylinder may result in rise of which of the following when exposed to heat may lead to explosion:
Correct
An increase in temperature results in increase in pressure of the refrigerant in the cylinder.
Incorrect
An increase in temperature results in increase in pressure of the refrigerant in the cylinder.
-
Question 3 of 15
3. Question
1 pointsThe relief valves present in the refrigeration system shall be in which of the following configuration:
Correct
Pressure Relief valves in refrigeration system shall always be arranged in parallel. If relief valves are arranged in series, failure of one relief valve during over pressurization will result in explosion. If they are provided in parallel arrangement ample refrigerant flow can be possible during over pressurization.
Incorrect
Pressure Relief valves in refrigeration system shall always be arranged in parallel. If relief valves are arranged in series, failure of one relief valve during over pressurization will result in explosion. If they are provided in parallel arrangement ample refrigerant flow can be possible during over pressurization.
-
Question 4 of 15
4. Question
1 pointsRefrigerants represented by letter _____ will have higher Toxicity:
Correct
Refrigerants with allowable exposure limit less than 400 ppm are considered as higher toxicity and designated by letter B
Incorrect
Refrigerants with allowable exposure limit less than 400 ppm are considered as higher toxicity and designated by letter B
-
Question 5 of 15
5. Question
1 pointsClass I Refrigerants will have a ozone depletion potential greater than:
Correct
All CFC refrigerants comes under Class I Refrigerants
Incorrect
All CFC refrigerants comes under Class I Refrigerants
-
Question 6 of 15
6. Question
1 pointsThe warmer the temperature of the refrigerant, the _____ will be evacuation of the refrigerant from the refrigeration system
Correct
Warmer the temperature of the refrigerant, denser will be refrigerant vapour and higher will be the system pressure. Recovery rate will be faster as the compressor in the recovery unit will recover more refrigerant per given time.
Incorrect
Warmer the temperature of the refrigerant, denser will be refrigerant vapour and higher will be the system pressure. Recovery rate will be faster as the compressor in the recovery unit will recover more refrigerant per given time.
-
Question 7 of 15
7. Question
1 pointsTo _______ is a process in which refrigerant to the level of new product specifications as determined by chemical analysis:
Correct
Reclaimed Refrigerant shall meet the ARI 700 purity standards and Recycled refrigerants need not require to maintain this purity standard.
Incorrect
Reclaimed Refrigerant shall meet the ARI 700 purity standards and Recycled refrigerants need not require to maintain this purity standard.
-
Question 8 of 15
8. Question
1 pointsRefrigerant in Condenser will be in which of the following phase:
Correct
Hot vapor refrigerant from compressor leaves to condenser and flows through the tubes of condenser. As refrigerant heat is removed in the condenser, refrigerant reaches saturation temperature and converts to high pressure liquid
Incorrect
Hot vapor refrigerant from compressor leaves to condenser and flows through the tubes of condenser. As refrigerant heat is removed in the condenser, refrigerant reaches saturation temperature and converts to high pressure liquid
-
Question 9 of 15
9. Question
1 pointsThe compound gauge is usually ______ in color and measures low pressure and vacuum:
Correct
Compound gauge measures low pressure and vacuum and color coded Blue. High pressure gauge is color coded Red. Yellow hose (compound gauge) is for service (add or remove refrigerant or remove contaminants from the system.
Incorrect
Compound gauge measures low pressure and vacuum and color coded Blue. High pressure gauge is color coded Red. Yellow hose (compound gauge) is for service (add or remove refrigerant or remove contaminants from the system.
-
Question 10 of 15
10. Question
1 pointsSince _______, knowingly venting any refrigerant is a violation of CAA:
Correct
Incorrect
-
Question 11 of 15
11. Question
1 pointsAs per CAA, improper record keeping is subjected to a penalty fine of ______ per day per violation:
Correct
Incorrect
-
Question 12 of 15
12. Question
1 pointsHFC refrigerants have Zero Ozone Depletion Potential & Zero Global Warming Potential:
Correct
HFC refrigerants have Zero Ozone Depletion Potential as it does not contain chlorine elements which is the major factor responsible for ozone depletion. However HFC refrigerants are green house gases and contributes to global warming
Incorrect
HFC refrigerants have Zero Ozone Depletion Potential as it does not contain chlorine elements which is the major factor responsible for ozone depletion. However HFC refrigerants are green house gases and contributes to global warming
-
Question 13 of 15
13. Question
1 pointsThe temperature at which non azeotropic blend first begins to condense:
Correct
Incorrect
-
Question 14 of 15
14. Question
1 pointsOzone layer in the stratosphere extends upto ______ miles above the earth’s surface:
Correct
Incorrect
-
Question 15 of 15
15. Question
1 pointsThe amount of heat added to the refrigerant in condenser to make it saturated and change its state is:
Correct
Incorrect