Question 1 of 12
1. Question
1 pointsCFC-12, CFC-11, and HFC-134a are code grouped as A-1 refrigerants
Correct
Incorrect
-
Question 2 of 12
2. Question
1 pointsThe refrigerant leaves the compressor as a ______:
Correct
Incorrect
-
Question 3 of 12
3. Question
1 pointsThe most efficient method of leak checking a charged low-pressure refrigeration unit is to pressurize the system by the use of controlled hot water or heater blankets:
Correct
Incorrect
-
Question 4 of 12
4. Question
1 pointsThe primary purpose of a purge unit is to remove non-condensables from the system
Correct
Incorrect
-
Question 5 of 12
5. Question
1 pointsTypical design burst pressure for a rupture disc on a low-pressure centrifugal chiller system is set at :
Correct
Incorrect
-
Question 6 of 12
6. Question
1 pointsThe ASHRAE Guideline 3-1996 states that if the pressure in a system rises from 1 mm Hg to a level above ____ during vacuum testing, the system should be leak checked
Correct
Incorrect
-
Question 7 of 12
7. Question
1 pointsThe ARI-certified, tested refrigerant-to-air-emission ratio should be below ______ of refrigerant per pound of air purged:
Correct
Incorrect
-
Question 8 of 12
8. Question
1 pointsTo ensure the purge unit will perform to its published efficiency rating, verify the unit is ARI-certified to:
Correct
Incorrect
-
Question 9 of 12
9. Question
1 pointsFrom Temperature and pressure chart, if you know the type of refrigerant and the _____, you can calculate the evaporation temperature in the evaporator
Correct
Incorrect
-
Question 10 of 12
10. Question
1 pointsAll recovery cylinders must be DOT approved and have a current hydrostatic test date stamped on them if they contain a refrigerant with a pressure above _____ at room temperature
Correct
Incorrect
-
Question 11 of 12
11. Question
1 pointsRegardless of the recovery method used, all Type II or Type III certified technicians must have at least one recovery machine capable of achieving the required evacuation level
Correct
Incorrect
-
Question 12 of 12
12. Question
1 pointsEPA regulations require that all commercial and industrial process refrigeration containing more than 50 lbs. of refrigerant be repaired when the annual leak rate exceeds _____
Correct
Incorrect