Quiz-summary
0 of 14 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
Information
EPA 608 Online Practice Test 9: Type 2 Quiz Questions Answers
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 14 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- Answered
- Review
-
Question 1 of 14
1. Question
1 pointsIn a refrigeration system, receiver is NOT part of the low side of the system
Correct
Incorrect
-
Question 2 of 14
2. Question
1 pointsIf a moisture indicating sight glass is used, it would be located _______ of the filter drier, but before the expansion
Correct
Incorrect
-
Question 3 of 14
3. Question
1 pointsThe amount of refrigerant that is absorbed is affected by which of the following parameters:. (Multiple Answer Question)
Correct
Incorrect
-
Question 4 of 14
4. Question
1 pointsWhich of the following gas is used for checking the leak in the refrigeration system:
Correct
Incorrect
-
Question 5 of 14
5. Question
1 pointsProper recovery techniques begin with the use of appropriate recovery equipment that has been certified by an EPA approved laboratory (UL or ETL) to meet or exceed _______.
Correct
Incorrect
-
Question 6 of 14
6. Question
1 pointsEPA regulations require that all Commercial and Industrial Process Refrigeration containing more than 50 lbs. of refrigerant MUST be repaired when the annual leak rate exceeds ______.
Correct
Incorrect
-
Question 7 of 14
7. Question
1 pointsA refrigerant cylinder that has a _______ indicates the cylinder is designed to hold recovered refrigerant
Correct
Incorrect
-
Question 8 of 14
8. Question
1 pointsAll recovery cylinders are _____ rated
Correct
Incorrect
-
Question 9 of 14
9. Question
1 pointsSystem dependent recovery devices should be used on systems that contain less than ______ of refrigerant
Correct
Incorrect
-
Question 10 of 14
10. Question
1 pointsLeaks should be checked in the recovery or recycling unit for every:
Correct
Incorrect
-
Question 11 of 14
11. Question
1 pointsThe ______ is designed to trap acid and particulates and to remove water from the refrigerant.
Correct
Incorrect
-
Question 12 of 14
12. Question
1 pointsType II certified technicians are not certified to work with ______ systems
Correct
Incorrect
-
Question 13 of 14
13. Question
1 pointsWhich of the following vaporize to get out of the accumulator
Correct
Incorrect
-
Question 14 of 14
14. Question
1 pointsEvacuating to _____ ambient pressure could cause air and moisture to be ingested into the recovered refrigerant
Correct
Incorrect